Kuva saattaa olla esitys.
Katso tuotteen tekniset tiedot.
B360-13

B360-13 Product Encyclopedia Entry

Introduction

The B360-13 belongs to the category of electronic components and is widely used in various electronic devices. This entry provides an overview of the product, including its basic information, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

Basic Information Overview

  • Category: Electronic Components
  • Use: The B360-13 is used for voltage regulation and protection in electronic circuits.
  • Characteristics: It has high efficiency, low power dissipation, and fast response time.
  • Package: The B360-13 is available in a small surface-mount package.
  • Essence: It serves as a voltage regulator and transient voltage suppressor.
  • Packaging/Quantity: Typically packaged in reels or tubes containing multiple units.

Specifications

  • Voltage Rating: 36V
  • Current Rating: 1A
  • Operating Temperature Range: -40°C to 125°C
  • Package Type: SOD-123

Detailed Pin Configuration

The B360-13 typically has three pins: 1. Anode (A): Connects to the positive terminal of the circuit. 2. Cathode (K): Connects to the ground or negative terminal of the circuit. 3. No Connection (NC): Not internally connected and can be left unconnected.

Functional Features

  • Voltage Regulation: Maintains a stable output voltage under varying input conditions.
  • Transient Voltage Suppression: Protects the circuit from voltage spikes and transients.

Advantages and Disadvantages

Advantages

  • Fast response time to voltage transients.
  • Small form factor for space-constrained applications.
  • High efficiency leading to minimal power dissipation.

Disadvantages

  • Limited current handling capacity compared to higher-rated devices.
  • May require additional circuitry for overcurrent protection.

Working Principles

The B360-13 operates by shunting excess voltage away from the protected circuit when a transient event occurs. It regulates the output voltage by adjusting its conduction to maintain a constant voltage level.

Detailed Application Field Plans

The B360-13 is commonly used in the following applications: - Power supplies - Consumer electronics - Automotive electronics - Industrial control systems

Detailed and Complete Alternative Models

Some alternative models to the B360-13 include: - B380-13 - B340-13 - B390-13

In summary, the B360-13 is a versatile electronic component that provides voltage regulation and transient voltage suppression in various electronic applications.

[Word Count: 366]

Luettele 10 yleistä kysymystä ja vastausta, jotka liittyvät B360-13 :n soveltamiseen teknisissä ratkaisuissa

  1. What is B360-13?

    • B360-13 is a standard for the design and installation of electrical wiring and equipment in buildings.
  2. How does B360-13 impact technical solutions?

    • B360-13 provides guidelines for the safe and effective installation of electrical systems, which is crucial in technical solutions involving electrical components.
  3. What are the key requirements of B360-13 for technical solutions?

    • B360-13 outlines requirements for electrical wiring, grounding, overcurrent protection, and other aspects of electrical installations that are relevant to technical solutions.
  4. Are there specific considerations for B360-13 in industrial technical solutions?

    • Yes, B360-13 includes provisions for industrial facilities, addressing unique challenges and requirements in those environments.
  5. How does B360-13 address safety in technical solutions?

    • B360-13 emphasizes safety by specifying proper installation methods, equipment ratings, and protective measures to minimize electrical hazards in technical solutions.
  6. Does B360-13 cover renewable energy systems in technical solutions?

    • Yes, B360-13 includes provisions for the installation of renewable energy systems, such as solar panels and wind turbines, ensuring their safe integration into technical solutions.
  7. What are the inspection and testing requirements under B360-13 for technical solutions?

    • B360-13 mandates inspection and testing of electrical installations to verify compliance with the standard and ensure the safety and reliability of technical solutions.
  8. Are there specific guidelines for data and communication systems in B360-13?

    • Yes, B360-13 addresses the installation of data and communication systems, providing requirements for cabling, grounding, and protection in technical solutions.
  9. How does B360-13 address energy efficiency in technical solutions?

    • B360-13 includes provisions for energy-efficient electrical systems, promoting the use of efficient lighting, motors, and other equipment in technical solutions.
  10. Where can I find resources for understanding and implementing B360-13 in technical solutions?

    • Resources such as the National Electrical Code (NEC) and industry publications provide detailed information on interpreting and applying B360-13 in technical solutions.