Katso tuotteen tekniset tiedot.
74HCT9046AD,118

74HCT9046AD,118

Basic Information Overview

  • Category: Integrated Circuit (IC)
  • Use: Voltage-controlled oscillator (VCO) and phase-locked loop (PLL) applications
  • Characteristics: High-speed operation, low power consumption, wide supply voltage range
  • Package: SOIC (Small Outline Integrated Circuit)
  • Essence: Analog multiplexer/demultiplexer with a built-in voltage-controlled oscillator (VCO) and phase-locked loop (PLL)

Specifications

  • Supply Voltage Range: 2 V to 12 V
  • Operating Temperature Range: -40°C to +125°C
  • Input Voltage Range: -0.5 V to VCC + 0.5 V
  • Output Voltage Range: -0.5 V to VCC + 0.5 V
  • Maximum Input Current: ±10 mA
  • Maximum Output Current: ±25 mA
  • Propagation Delay Time: 15 ns (typical)
  • Power Dissipation: 500 mW (maximum)

Detailed Pin Configuration

The 74HCT9046AD,118 IC has a total of 16 pins. The pin configuration is as follows:

  1. VCC: Positive power supply
  2. GND: Ground reference
  3. XIN: External input for the voltage-controlled oscillator (VCO)
  4. XOUT: Output of the voltage-controlled oscillator (VCO)
  5. CLK: Clock input for the phase-locked loop (PLL)
  6. RST: Reset input for the phase-locked loop (PLL)
  7. CP: Charge pump output for the phase-locked loop (PLL)
  8. VCO_OUT: Output of the voltage-controlled oscillator (VCO)
  9. VCO_IN: Input for the voltage-controlled oscillator (VCO)
  10. VCO_GND: Ground reference for the voltage-controlled oscillator (VCO)
  11. VCO_VCC: Positive power supply for the voltage-controlled oscillator (VCO)
  12. GND: Ground reference
  13. SEL1: Select input 1 for the analog multiplexer/demultiplexer
  14. SEL2: Select input 2 for the analog multiplexer/demultiplexer
  15. IN/OUT: Analog input/output for the analog multiplexer/demultiplexer
  16. VCC: Positive power supply

Functional Features

  • The 74HCT9046AD,118 is an integrated circuit that combines an analog multiplexer/demultiplexer with a voltage-controlled oscillator (VCO) and phase-locked loop (PLL).
  • It allows the selection of different analog inputs or outputs using the select inputs (SEL1 and SEL2).
  • The voltage-controlled oscillator (VCO) generates a frequency that can be controlled by an external input (XIN) or internally through the PLL.
  • The phase-locked loop (PLL) ensures that the output frequency remains locked to the input clock signal (CLK).
  • The charge pump output (CP) provides a current source/sink for the PLL loop filter.

Advantages and Disadvantages

Advantages: - High-speed operation allows for efficient signal processing. - Low power consumption makes it suitable for battery-powered applications. - Wide supply voltage range provides flexibility in various electronic systems.

Disadvantages: - Limited number of analog inputs/outputs compared to dedicated multiplexers/demultiplexers. - Requires careful consideration of noise and interference due to its analog nature.

Working Principles

The 74HCT9046AD,118 operates based on the principles of analog multiplexing, voltage-controlled oscillation, and phase-locked loops. The analog multiplexer/demultiplexer allows the selection of different analog inputs or outputs. The voltage-controlled oscillator (VCO) generates a frequency that can be controlled by an external input or internally through the phase-locked loop (PLL). The PLL ensures that the output frequency remains locked to the input clock signal. The charge pump output provides the necessary current source/sink for the PLL loop filter.

Detailed Application Field Plans

The 74HCT9046AD,118 is commonly used in various applications, including: 1. Frequency synthesizers 2. Clock recovery circuits 3. Data communication systems 4. Frequency modulation/demodulation circuits 5. Phase-locked loop (PLL) circuits

Detailed and Complete Alternative Models

Some alternative models that serve similar functions to the 74HCT9046AD,118 include: 1. CD74HC4046: High-speed CMOS logic IC with a phase-locked loop (PLL) 2. MC14046B: Analog multiplexer/demultiplexer with a built-in voltage-controlled oscillator (VCO) 3. HEF4046B: Phase-locked loop (PLL) IC with a wide supply voltage range

These alternative models offer similar features and can be used as replacements depending on specific requirements

Luettele 10 yleistä kysymystä ja vastausta, jotka liittyvät 74HCT9046AD,118 :n soveltamiseen teknisissä ratkaisuissa

Sure! Here are 10 common questions and answers related to the application of 74HCT9046AD,118 in technical solutions:

  1. Q: What is the function of the 74HCT9046AD,118? A: The 74HCT9046AD,118 is a phase-locked loop (PLL) frequency synthesizer IC used for frequency synthesis and clock generation.

  2. Q: What is the operating voltage range of the 74HCT9046AD,118? A: The operating voltage range is typically between 4.5V and 5.5V.

  3. Q: Can the 74HCT9046AD,118 be used for both analog and digital applications? A: Yes, it can be used for both analog and digital applications due to its versatile design.

  4. Q: How many outputs does the 74HCT9046AD,118 have? A: It has three outputs - VCO output, reference frequency output, and lock indicator output.

  5. Q: What is the frequency range of the VCO output? A: The VCO output frequency range is typically from 0 Hz to 20 MHz.

  6. Q: Can the 74HCT9046AD,118 be used for frequency modulation (FM) applications? A: Yes, it can be used for FM applications by modulating the control voltage input.

  7. Q: Does the 74HCT9046AD,118 require external components for operation? A: Yes, it requires external passive components such as resistors and capacitors for proper operation.

  8. Q: What is the lock indicator output used for? A: The lock indicator output provides a signal indicating whether the PLL is locked onto the reference frequency or not.

  9. Q: Can the 74HCT9046AD,118 be used in high-frequency applications? A: Yes, it can be used in high-frequency applications as it is designed to operate up to 20 MHz.

  10. Q: Are there any specific precautions to consider when using the 74HCT9046AD,118? A: It is important to follow the recommended operating conditions and guidelines provided in the datasheet to ensure proper functionality and reliability of the IC.

Please note that these answers are general and may vary depending on the specific application and requirements.