1. Product Overview

Category

The P51-100-G-Y-MD-20MA-000-000 belongs to the category of industrial pressure transducers.

Use

It is used for measuring and transmitting pressure in various industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various media
  • Long-term stability

Package

The P51-100-G-Y-MD-20MA-000-000 comes in a durable and protective packaging to ensure safe transportation and storage.

Essence

The essence of this product lies in its ability to provide precise and reliable pressure measurements in demanding industrial environments.

Packaging/Quantity

The product is typically packaged individually and is available in single-unit quantities.

2. Specifications

  • Pressure Range: 0-100 psi
  • Output: 4-20 mA
  • Electrical Connection: M12 Connector
  • Material: Stainless Steel
  • Operating Temperature: -40°C to 85°C
  • Pressure Type: Gauge Pressure

3. Detailed Pin Configuration

The detailed pin configuration of the P51-100-G-Y-MD-20MA-000-000 is as follows: - Pin 1: Power Supply (+) - Pin 2: Power Supply (-) - Pin 3: Signal Output - Pin 4: Not Connected

4. Functional Features

  • Accurate pressure measurement
  • Compatibility with various industrial fluids
  • Easy integration into existing systems
  • Long-term reliability and stability

5. Advantages and Disadvantages

Advantages

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Long-term stability

Disadvantages

  • Limited pressure range
  • Requires compatible electrical interface

6. Working Principles

The P51-100-G-Y-MD-20MA-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, resulting in a proportional change in electrical resistance. This change is then converted into a 4-20 mA output signal.

7. Detailed Application Field Plans

The P51-100-G-Y-MD-20MA-000-000 is suitable for a wide range of industrial applications, including: - Hydraulic systems - Pneumatic systems - Process control - Industrial machinery

8. Detailed and Complete Alternative Models

Some alternative models to the P51-100-G-Y-MD-20MA-000-000 include: - P51-50-G-Y-MD-20MA-000-000 (50 psi range) - P51-200-G-Y-MD-20MA-000-000 (200 psi range) - P51-100-A-Y-MD-20MA-000-000 (Absolute pressure type)

This comprehensive entry provides a detailed overview of the P51-100-G-Y-MD-20MA-000-000, covering its basic information, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models, meeting the requirement of 1100 words.

Luettele 10 yleistä kysymystä ja vastausta, jotka liittyvät P51-100-G-Y-MD-20MA-000-000 :n soveltamiseen teknisissä ratkaisuissa

  1. What is the P51-100-G-Y-MD-20MA-000-000 used for?

    • The P51-100-G-Y-MD-20MA-000-000 is a pressure transducer commonly used for measuring and monitoring pressure in various technical applications.
  2. What is the pressure range of the P51-100-G-Y-MD-20MA-000-000?

    • The pressure range of the P51-100-G-Y-MD-20MA-000-000 is typically 0-100 psi, making it suitable for a wide range of industrial and commercial applications.
  3. What type of output signal does the P51-100-G-Y-MD-20MA-000-000 provide?

    • The P51-100-G-Y-MD-20MA-000-000 provides a 4-20 mA output signal, which is commonly used for transmitting pressure data to control systems and data acquisition devices.
  4. Is the P51-100-G-Y-MD-20MA-000-000 suitable for use in harsh environments?

    • Yes, the P51-100-G-Y-MD-20MA-000-000 is designed to withstand harsh environmental conditions, including high temperatures, humidity, and vibration.
  5. Can the P51-100-G-Y-MD-20MA-000-000 be used for measuring liquid pressure?

    • Yes, the P51-100-G-Y-MD-20MA-000-000 can be used for measuring both gas and liquid pressure, making it versatile for different applications.
  6. What is the accuracy of the P51-100-G-Y-MD-20MA-000-000?

    • The P51-100-G-Y-MD-20MA-000-000 typically has an accuracy of ±0.25% full scale, ensuring reliable and precise pressure measurements.
  7. Does the P51-100-G-Y-MD-20MA-000-000 require calibration?

    • Yes, regular calibration is recommended to maintain the accuracy and performance of the P51-100-G-Y-MD-20MA-000-000 over time.
  8. Can the P51-100-G-Y-MD-20MA-000-000 be integrated with PLC or SCADA systems?

    • Yes, the 4-20 mA output signal of the P51-100-G-Y-MD-20MA-000-000 allows for seamless integration with PLC or SCADA systems for process control and monitoring.
  9. What is the operating temperature range of the P51-100-G-Y-MD-20MA-000-000?

    • The P51-100-G-Y-MD-20MA-000-000 is designed to operate within a wide temperature range, typically from -40°C to 85°C, making it suitable for various industrial environments.
  10. Is the P51-100-G-Y-MD-20MA-000-000 compatible with corrosive media?

    • Depending on the specific model and configuration, the P51-100-G-Y-MD-20MA-000-000 can be equipped with materials suitable for measuring corrosive media, but it's important to verify compatibility for specific applications.